Product Identification

Product ID:HEMATOXYLIN SOLUTION
MSDS Date:03/26/1992
FSC:6810
NIIN:00F048684
MSDS Number: BZFVP

Responsible Party
ONCOR INC
209 PERRY PKY SUITE 7
GAITHERSBURG, MD 20877-5000
US

Emergency Phone: 301-963-3500/800-776-6267

Info Phone: 301-963-3500/800-776-6267

Cage: 016E9

Contractor
ONCOR INC
GAITHERSBURG, MD 20877-5000 US

Telephone: 301-963-3500/800-776-6267

Cage: 016E9

Ingredients

HEMATOXYLIN

CAS: 517-28-2

RTECS: MH7875000

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE
Effects of Overexposure:NONE

First Aid

First Aid:SKIN/EYES: FLUSH W/WATER. INGESTION: INDUCE VOMITING. OBTAIN
MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:WATER, CO2, FOAM.
Fire Fighting Procedures:WEAR SCBA & PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:WEAR PROTECTIVE EQUIPMENT. ABSORB ON
SAND/VERMICULITE & PLACE IN CLOSED CONTAINERS FOR DISPOSAL.
VENTILATE AREA & WASH SITE AFTER MATERIAL PICKUP IS COMPLETE.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMP IN A DRY LOCATION.
KEEP PRODUCT OUT OF LIGHT. WEAR LABORATORY APRONS/APPROVED CLOTHING
& GLOVES.

Exposure Controls

Respiratory Protection:NONE REQUIRED WHERE ADEQUATE VENTILATION
CONDITIONS EXIST.
Ventilation:GENERAL/LOCAL EXHAUST
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:LABORATORY APRONS, PROTECTIVE CLOTHING.
Supplemental Safety and Health

Chemical Properties

Appearance and Odor:DARK BLUE SOLUTION
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS
Stability Condition to Avoid:ROOM TEMP
Hazardous Decomposition Products:TOXIC FUMES OF CO, CO2. MAY DISCOLOR
ON EXPOSURE TO LIGHT.

Disposal

Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS. FLUSH TO SEWER IF PERMITTED/BURN IN A CHEMICAL
INCINERATOR.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.